New shape with classic LCD screen. Rounded frame design brings the product new flexibility, classic screen with large font and good visibility, easy to read in any situation.
Size | 100.6mm * 60.2mm * 84.4mm |
---|---|
Function | Battery, Headlight, Mile/KM, ODO, PAS Level, Speed, Trip, Trip Time, Walk Assistance, Watt |
Communication | CAN BUS, LIN, UART |
Holder | 22.2mm, 25.4mm, 31.8mm |
Voltage | 24V, 36V, 48V |
USB Charging | 5V/500mA, With, With 5V/1A, Without |
Certificate | CE, EN15194:2017, IPX6, RoHS |
Dear users,
To ensure the better performance of your e-bike, please read through the E5227 LCD product introduction carefully before using it. We will use the brief words to inform you of all the details (including hardware installation, setting, and normal use of the display) when using our display. Meanwhile, the introduction will also help you solve possible confusion and barriers.
E5227 LCD housing material: PC. And the color of the housing is black. Working temperature scope: -20℃—+60℃, the shell material can ensure the normal use and good mechanical performance of the products.
Display Size and Installation Size(Unit: mm)
E5227 LCD is equipped with a special N3-button unit.N3 button shape is as follows:
The N3 button is connected to the bottom lead of the E5227 LCD display.
In the follow-up instructions, the button ‘M’ is named [MODE]. The button ‘Up arrow’ is named [UP], and the button “Down arrow” is named [DOWN].
In addition, 30 button as below is also optional, to be mounted on the left side of the handlebar or on the right side of the handlebar. Its shape is as follows:
The 30 button is connected to the bottom lead of the E5227 LCD display. In the follow-up instructions,
The button ‘M’ is named [MODE]. The button ‘Up arrow’ is named [UP], and the button ‘Down arrow’ is named [DOWN].
The E5227 LCD offers you a variety of features and displays to suit your cycling needs. The displayed contents are:
In the subsequent description, the button ‘M’ is named [MODE]. The button ‘Up arrow’ is named [UP], and the button ‘Down arrow’ is named [DOWN].
Pay attention to safety during use, do not connect or disconnect the display while it is powered on.
Fix the display on the handlebar and adjust the proper angle of view. In the case that the e-bike is powered off, the connector of the display is inserted into the connector corresponding to the controller to complete the installation.
Hold the [MODE] button, the display starts to work and provides the controller with working power. In the power-on state, hold the [MODE] button to turn off the power of the electric vehicle. In the power-off state, the display no longer uses the battery’s power supply, and the display’s leakage current is less than 1uA.
Note: If the e-bike is not used for more than 10 minutes, the display will automatically shut down.
After the display is turned on, the display shows the following interface:
Press [MODE] to switch between TRIP and ODO. This feature makes it easy for users to view the current mileage (TRIP) and accumulated total mileage (ODO).
After the e-bike is turned on, the display shows the current speed by default.
Hold [MODE] and [UP] buttons simultaneously for 2 seconds to display the average speed (AVG) of the current ride. Hold [MODE] and [UP] buttons simultaneously again for 2 seconds to display the maximum speed (MAX), hold [MODE] and [UP] buttons simultaneously again for 2 seconds, return to the current speed and repeat this cycle.
Hold [DOWN] for 2 seconds, the e-bike enters the mode of power assist walk. The e-bike travels at a constant speed of 6 Km/h, WALK symbol flashes on the screen.
Note: The power-saving function can only be used when the user pushes the e-bike. Do not use it while riding.
Hold the [UP] button for 2 seconds, the display’s backlight is turned on, and the controller is notified to turn on the headlights. The LCD backlight can be turned on when there is insufficient external light or driving at night. Hold the [UP[ button for 2 seconds again, and the LCD backlight turns off.
Press the [UP] or [DOWN] button to switch the PAS level of the e-bike and change the output power of the motor. The default output power range of the display is PAS 1-5, and preset level 1.
When the battery voltage is high, the five-segment LCD is on. When the battery is under voltage, the outer frame of the battery flashes, indicating that the battery is seriously under-voltage and has to be charged immediately.
The display can show the output power of the current motor. The display mode is as shown below.
When the e-bike electronic control system fails, the display will automatically report the error code. See Table 1 for the definition of the detailed error code.
Note: The fault display interface can only be exited when the fault is eliminated. After the fault occurs, the e-bike will not be able to continue riding.
Display with USB interface, this interface provides charging power for mobile phones, output 5VDC/500mA. When the display is off, connect the mobile phone data cable between the display and the mobile phone. When then turn on the display, it shows ‘USB’ every 3S, indicating that the mobile phone is being charged; if the display is turned off at this time, the USB interface still provides the mobile phone charging function. In any state, unplug the phone and the charging will automatically terminate.
Make sure the connectors are docked firmly and turn on the e-bike.
Hold the [MODE] button to start up. In the power-on state, hold the [UP] and [DOWN] buttons simultaneously for 2 seconds, and the display enters the setting state.
CL stands for single trip clearance, and the setting parameter is optional N/Y. The default N means that the single trip distance is not cleared. Y/N can be selected by [UP] / [DOWN], Y means that the single trip distance needs to be cleared, and N means that the single trip distance does not need to be cleared.
BL stands for backlight. Parameters 1, 2, and 3 can be set to indicate the brightness of the backlight. The factory default value is 1. The backlight brightness parameter can be changed by [UP]/[DOWN]. 1 is the darkest and 3 is the brightest.
The unit represents the display unit. The parameter Metric/English can be set. The factory default is metric. The parameters can be changed by [UP]/[DOWN].
Exit Setting
In the setting state, shortly press the [MODE] button to confirm the input and enter the next setting, and hold the [MODE] button to save and exit the setting state.
Hold [UP] and [DOWN] buttons simultaneously for 2 seconds to enter the normal setting state; then hold [UP] and [MODE] buttons simultaneously for 2 seconds to enter the power-on password setting state.
The display prompts “PAS.2”, indicating that you need to enter the power-on password. Press the [MODE] button to shift, and increase/decrease the input value by [UP] /[DOWN]. After the 4-digit password is entered, press the [MODE] key to confirm. If the password is correct, enter the power-on password user setting interface, otherwise, it will stay in the password input state. Hold the [MODE] button to exit. The factory default is 1234.
By [UP]/[DOWN] to select Y/N. Y means that the power-on password is required, and N means that the power-on password is not required. Press [MODE] to confirm and enter the password modification interface.
PSD indicates the password. Press [MODE] to shift and increase/decrease the value by [UP]/[DOWN]. After the modification is completed, hold the [MODE] button to save the confirmation and exit the setting state.
Hold[UP] and [DOWN] buttons simultaneously for 2 seconds to enter the normal setting state; then Hold [DOWN] and [DOWN] buttons simultaneously for 2 seconds to enter the operation parameter setting state.
The display prompts “PAS.1”, indicating that you need to enter the permission password. Press the [MODE] button to shift, and increase/decrease the input value by [UP]/[DOWN]. After the 4-digit password is entered, press the [MODE] button to confirm. If the password is correct, enter the power-on password setting interface, otherwise, it will stay in the password input state. Hold [MODE] to exit. The permission password is 0512.
LD stands for wheel diameter setting. Available values are: 16inch, 18 inch, 20 inch, 22 inch, 24 inch, 26 inch, 700C, 28 inch, 29 inch. Use [UP]/[DOWN] to select the wheel diameter corresponding to the e-bike to ensure the accuracy of the speed display and mileage display. Press [MODE] to confirm and enter the speed limit setting interface. The factory default wheel diameter value is 26inch.
LS indicates the speed limit setting. The default maximum riding speed is 25Km/h. Change this value to set the maximum riding speed of the e-bike. When the electric motor exceeds the set value, the controller will stop supplying power to the motor to protect the rider’s safety.
The maximum speed setting can be selected from 12Km/h to 25Km/h. It can be set by [UP]/[DOWN]. After the modification is completed, press and hold the [MODE] button to save the confirmation and exit the setting.
In order to enhance the personalized use of this product, we have specifically added this setting. It can be set for different requirements of users. In this setting, the display’s battery indicator setting, PAS level setting, current limit setting, PAS sensor setting, speed sensor setting, throttle function setting, and system setting are included. A total of seven items and detailed settings are shown in table 3.
Hold [UP] and [DOWN] buttons simultaneously for 2 seconds to enter the normal setting state; then hold the [UP] & [DOWN] buttons simultaneously again for 2 seconds to enter the personalized parameter setting state.
The display prompts “PAS.3”, indicating that you need to enter the permission password. Press [MODE] button to shift, and increase/decrease the input value by [UP]/[DOWN]. After the 4-digit password is entered, press the [MODE] button to confirm. If the password is correct, enter the power-on password setting interface, otherwise, it will stay in the password input state. Hold [MODE] to exit. The permission password is 2962.
By [UP]/[DOWN] to select the content to be set, and press [MODE] to enter the corresponding setting interface.
VOL indicates the battery indicator setting. It is required to input the voltage values of 1 to 5 one by one. Take the first battery value as an example: “1” on the display indicates the first voltage and “31.5” is the first battery value. Change the value by increasing/decreasing with [UP]/[DOWN]. Press [MODE] to confirm and enter the next battery value setting. After the 5 power values are set, press [MODE] to confirm and return to the personalization parameter setting interface.
SCA indicates the PAS parameter setting. Eight modes are provided for selection: 0-3, 1-3, 0-5, 1-5, 0-7, 1-7, 0-9, 1-9. Switch between [UP]/[DOWN], press [MODE] to confirm, and enter the corresponding PAS ratio value setting interface.
By setting the PAS proportion, you can adjust the speed of each gear to meet the needs of different riders.
Taking the first gear as an example, “15 – 30” is the recommended range of the PAS proportion, and “22” is the current value of the first gear (ie, the output is 22%). By increase/decrease settings with [UP]/[DOWN]. Press [MODE] to confirm and enter the next PAS proportion setting. After the setting is finished, press [MODE] to confirm and return to the personalization parameter setting interface. Refer to table 4 for details.
CUR indicates the current limit setting. The current limit can be set from 7.0-18.0A. Change the maximum current value of the controller by [UP]/[DOWN]. Hold [MODE] to confirm and return to the personalization parameter setting interface. The factory default value of the display is 15A.
Depending on the hardware of the controller, the controller may not be able to reach the set 18A.
Run indicates the PAS sensor direction setting. The display shows run.F/b. run. F stands for forward and run. b stands for reverse. Switch by [UP]/[DOWN]. Press [MODE] to confirm and enter the PAS sensor sensitivity setting. The factory default value of the sensor direction is positive.
The display shows SCN, indicating the sensitivity of the PAS sensor. The setting range is 2-9. 2 indicates the highest sensitivity and 9 indicates the lowest sensitivity. Increase/decrease setting values by [UP]/[DOWN]. Press [MODE] to confirm and enter the PAS sensor proportion parameter setting interface. The factory default value is 2.
N- represents the PAS sensor proportional parameter. The power sensor parameter values can be selected by [UP]/[DOWN]. The larger the value, the more obvious the PAS feeling. Hold [MODE] to confirm and return to the personalization parameter setting interface.
SPS indicates the speed sensor setting. It can be set according to the number of magnet heads mounted on the wheel of the e-bike, and the setting range is 1-9. Modify it by pressing [UP]/[DOWN]. Hold [MODE] to confirm and return to the personalization parameter setting interface. The factory default value is 1.
HL indicates the throttle’s push cruise control. HL: N means that the throttle does not has this function, and HL: Y means that throttle has this function, that is, when turning the throttle, the display enters the push cruise control mode. Y/N can be switched by [UP]/[DOWN]. If you select N, press [MODE] shortly to confirm and enter the throttle PAS level setting interface, otherwise, there is no response. Hold [MODE] to confirm and return to the display’s personalization parameter setting interface. The factory default value of the display is N.
HF indicates the throttle level setting. HF: N means that the throttle doesn’t split levels according to the PAS ratio. If the throttle level splitting is enabled, the maximum output of the motor can only reach the speed of the corresponding PAS level shown on the display when turning the throttle; if no level splitting, it means that when the throttle is turned, the speed will not be limited to the PAS level shown on the display, it can reach to the rated maximum speed. Y/N can be set by [UP]/[DOWN]. Press and hold [MODE] to confirm and return to the display’s personalization parameter setting interface. The factory default value of the display is N.
DL represents the battery delay time. The battery delay time 3/6/12s can be selected by [UP]/[DOWN]. Press [MODE] to confirm and enter the maximum speed limit setting interface. The default value is 3s.
MAX SPEED indicates the maximum speed limit. The maximum speed limit value can be set by [UP]/[DOWN], and the setting range is 25-40 Km/h. Press [MODE] to confirm, and enter the push walk mode to enable the setting interface. The factory default is 25Km/h.
PUS indicates that push cruise control enables the setting. Y/N can be switched by [UP]/[DOWN]. Y means enable, that is, hold [DOWN], the push cruise control function can be realized; N means no enable, that is, no push cruise control function. Press [MODE] to confirm and enter the push cruise control speed setting. The factory default value of the display is Y.
PU indicates the push speed setting. By setting the assist speed value, you can adjust the pushing speed to meet the needs of different riders. Adjusted by [UP]/[DOWN], the adjustable range is “10-50”. Press [MODE] to confirm and enter the slow start setting interface. The display defaults to 25 (ie, 25% output).
SP indicates the slow start-up setting. The adjustable range is 1-4. 4 is the slowest. Select with [UP]/[DOWN]. Press and hold [MODE] to confirm and return to the display’s personalization parameter setting interface. The display defaults to factory default 1.
In the personalized parameter setting state: press [MODE] to confirm the input to enter the next setting; hold [MODE] to confirm the current setting and exit the current setting state; hold [DOWN] to cancel the current operation, exit without saving the current set data.
Note: The display automatically exits the setting state without any operation for one minute.
DEF means to restore the default parameters. Hold [DOWN] and [MODE] buttons simultaneously for 2 seconds to enter the Restore Default Parameters interface. Switch Y or N with [UP]/[DOWN]. Y indicates that the default parameters need to be restored. Hold [MODE] to confirm. If you select Y, you need to enter the permission password to restore the default parameters.
The permission password is 0368. Press [MODE] to shift and increase/decrease the value by [UP]/[DOWN]. After the 4-digit password is entered, press [MODE] to confirm. The display will automatically exit after a successful recovery.
Note: In the recovery default, the battery indicator, ODO, and TRIP are unrecoverable, but the power-on password is in recovery.
Q: Why can’t turn on the display?
A: Check if the battery power is turned on, the outer leakage cable is broken or not.
Q: What should I do if the display shows an error code?
A: Timely repair at the e-bike repair shop.
In the case of normal use, due to the quality problems caused by the product itself, the company will be responsible for the warranty during the warranty period.
The warranty: 24 months since the display is out of the factory.
Regarding the storage and handling of the product, please comply with local laws and regulations and environmental requirements.
Standard Connector Wire Sequence
Table: Standard connector wire sequence table
Note: Some products have waterproof connectors for the leads, and the user cannot see the color of the leads in the harness.
This operating instruction is general-purpose software (version V1.0). Some of the versions of the e-bike LCD may have slight differences, all with the actual use version.
Note: Here is a more general error code for different e-system for your reference.
WhatsApp us
We will email you within 1 day with the suffix “@topeparts.com”.
Mobile: +1 (631) 780 4666
Automated page speed optimizations for fast site performance